{"product_id":"tempest-gasoline-powered-smoke-ejectors","title":"Tempest GASOLINE-POWERED SMOKE EJECTORS","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"5f16af74-7919-48e6-8452-93b9fee22567\" data-testid=\"conversation-turn-54\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"0eb0582c-727a-4c47-a05c-c35b7e5fdd8a\" dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-2\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-start=\"383\" data-end=\"430\"\u003eTempest GB-Series Gas-Powered Smoke Ejectors\u003c\/h2\u003e\n\u003cp data-start=\"432\" data-end=\"815\"\u003eThe Tempest GB-Series Gas-Powered Smoke Ejectors are robust, portable ventilation units designed for emergency response and fire service applications where controlled smoke and heat removal is required. Built with reliable Honda gasoline engines and engineered airflow pathways, these smoke ejectors provide dependable performance for rapid deployment and efficient smoke extraction.\u003c\/p\u003e\n\u003ch3 data-start=\"817\" data-end=\"841\"\u003eOperational Overview\u003c\/h3\u003e\n\u003cp data-start=\"843\" data-end=\"1307\"\u003eThe GB-Series smoke ejectors utilize direct-drive gasoline engines connected to high-efficiency impellers to produce consistent airflow capable of clearing smoke and heat from interior environments. Their compact designs are intended for quick setup and operation during fireground and training scenarios. The units are optimized to support positive pressure ventilation, overhaul ventilation, and general smoke control tasks where electrical power is unavailable.\u003c\/p\u003e\n\u003ch3 data-start=\"1309\" data-end=\"1325\"\u003eConstruction\u003c\/h3\u003e\n\u003cp data-start=\"1327\" data-end=\"1681\"\u003eEach GB-Series smoke ejector is constructed with a rugged housing and balanced impeller to ensure long-term operational reliability in demanding environments. Engine components and airflow systems are engineered for simplified maintenance and dependable performance. The compact footprint and integrated handles facilitate easy transport and positioning.\u003c\/p\u003e\n\u003ch3 data-start=\"1683\" data-end=\"1699\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"1701\" data-end=\"1744\"\u003eThese smoke ejectors are commonly used for:\u003c\/p\u003e\n\u003cul data-start=\"1746\" data-end=\"1949\"\u003e\n\u003cli data-start=\"1746\" data-end=\"1803\"\u003e\n\u003cp data-start=\"1748\" data-end=\"1803\"\u003eRapid smoke extraction during firefighting operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1804\" data-end=\"1845\"\u003e\n\u003cp data-start=\"1806\" data-end=\"1845\"\u003eOverhaul ventilation and heat removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1846\" data-end=\"1891\"\u003e\n\u003cp data-start=\"1848\" data-end=\"1891\"\u003eEmergency response and training scenarios\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1892\" data-end=\"1949\"\u003e\n\u003cp data-start=\"1894\" data-end=\"1949\"\u003eSituations where fuel-powered ventilation is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1951\" data-end=\"1989\"\u003eTechnical Specifications (General)\u003c\/h3\u003e\n\u003cp data-start=\"1991\" data-end=\"2123\"\u003eDevice type: Gas-powered smoke ejector\u003cbr data-start=\"2029\" data-end=\"2032\"\u003ePower source: Gasoline engine\u003cbr data-start=\"2061\" data-end=\"2064\"\u003eDrive type: Direct drive\u003cbr data-start=\"2088\" data-end=\"2091\"\u003eOperation: Manual start engine\u003c\/p\u003e\n\u003cp data-start=\"2125\" data-end=\"2180\"\u003e\u003cem data-start=\"2125\" data-end=\"2180\"\u003e(Individual model specifications are detailed below.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"2182\" data-end=\"2210\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2212\" data-end=\"2719\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2212\" data-end=\"2342\"\u003e\n\u003ctr data-start=\"2212\" data-end=\"2342\"\u003e\n\u003cth data-start=\"2212\" data-end=\"2220\" data-col-size=\"sm\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2220\" data-end=\"2235\" data-col-size=\"sm\"\u003eFan Diameter\u003c\/th\u003e\n\u003cth data-start=\"2235\" data-end=\"2244\" data-col-size=\"sm\"\u003eEngine\u003c\/th\u003e\n\u003cth data-start=\"2244\" data-end=\"2265\" data-col-size=\"sm\"\u003eEngine Output (HP)\u003c\/th\u003e\n\u003cth data-start=\"2265\" data-end=\"2287\" data-col-size=\"sm\"\u003eRated Airflow (CFM)\u003c\/th\u003e\n\u003cth data-start=\"2287\" data-end=\"2312\" data-col-size=\"sm\"\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003cth data-start=\"2312\" data-end=\"2321\" data-col-size=\"sm\"\u003eWeight\u003c\/th\u003e\n\u003cth data-start=\"2321\" data-end=\"2342\" data-col-size=\"sm\"\u003ePart Number \/ SKU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2475\" data-end=\"2719\"\u003e\n\u003ctr data-start=\"2475\" data-end=\"2595\"\u003e\n\u003ctd data-start=\"2475\" data-end=\"2503\" data-col-size=\"sm\"\u003eGB-16-S-3.5 Smoke Ejector\u003c\/td\u003e\n\u003ctd data-start=\"2503\" data-end=\"2512\" data-col-size=\"sm\"\u003e16 in.\u003c\/td\u003e\n\u003ctd data-start=\"2512\" data-end=\"2533\" data-col-size=\"sm\"\u003eHonda GX120 engine\u003c\/td\u003e\n\u003ctd data-start=\"2533\" data-end=\"2542\" data-col-size=\"sm\"\u003e3.5 HP\u003c\/td\u003e\n\u003ctd data-start=\"2542\" data-end=\"2550\" data-col-size=\"sm\"\u003e9,372\u003c\/td\u003e\n\u003ctd data-start=\"2550\" data-end=\"2573\" data-col-size=\"sm\"\u003e18.75″ × 14″ × 19.5″\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2583\" data-col-size=\"sm\"\u003e54 lbs.\u003c\/td\u003e\n\u003ctd data-start=\"2583\" data-end=\"2595\" data-col-size=\"sm\"\u003e911-1014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2596\" data-end=\"2719\"\u003e\n\u003ctd data-start=\"2596\" data-end=\"2624\" data-col-size=\"sm\"\u003eGB-16-S-4.8 Smoke Ejector\u003c\/td\u003e\n\u003ctd data-start=\"2624\" data-end=\"2633\" data-col-size=\"sm\"\u003e16 in.\u003c\/td\u003e\n\u003ctd data-start=\"2633\" data-end=\"2654\" data-col-size=\"sm\"\u003eHonda GX160 engine\u003c\/td\u003e\n\u003ctd data-start=\"2654\" data-end=\"2663\" data-col-size=\"sm\"\u003e4.8 HP\u003c\/td\u003e\n\u003ctd data-start=\"2663\" data-end=\"2672\" data-col-size=\"sm\"\u003e11,172\u003c\/td\u003e\n\u003ctd data-start=\"2672\" data-end=\"2697\" data-col-size=\"sm\"\u003e18.75″ × 16.2″ × 19.5″\u003c\/td\u003e\n\u003ctd data-start=\"2697\" data-end=\"2707\" data-col-size=\"sm\"\u003e78 lbs.\u003c\/td\u003e\n\u003ctd data-start=\"2707\" data-end=\"2719\" data-col-size=\"sm\"\u003e911-1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2721\" data-end=\"2730\"\u003eNotes\u003c\/h3\u003e\n\u003cp data-start=\"2732\" data-end=\"2989\"\u003eSpecifications and configurations are based on manufacturer-published website information and provided price sheet data. Where conflicts exist, price sheet values take precedence. Product specifications and availability are subject to change without notice.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Tempest","offers":[{"title":"3.5 HP Honda GX","offer_id":45140765737099,"sku":"911-1014","price":2789.0,"currency_code":"USD","in_stock":true},{"title":"4.8 HP Honda GX","offer_id":45140765769867,"sku":"911-1020","price":2389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8346\/8683\/files\/GBS18-Angle-right-Reverse-150x150_df567126-791a-4355-8574-3a1f6c68e0ed.png?v=1770228798","url":"https:\/\/mainresponse.com\/products\/tempest-gasoline-powered-smoke-ejectors","provider":"Main Response","version":"1.0","type":"link"}